EFBG |
Proportional Electro-Hydraulic Relief and Flow Valve
How to order
| EFBG- | 03- | 125 | C |
| serial no. | Port Size |
03 : 60, 160, 125 l/min
|
C : 140 bar H : 210 bar |
SPEC.
| Serial no. | EFBG | |
| Max. Operating Pressure | 210 bar | |
| Max. Flow (l/min.) |
03: 125 |
|
| Flow System |
Flow Adjusting Range |
03: 1~125 06: 2~250 10: 5~500 |
| Internal Resistance (A to B) | 5 bar | |
| Rated Current | 750 mA | |
| Coil Resistance | 40 Ω | |
| Magnetic Hysteresis | <7% | |
| Repeatability | <1% | |
| Pressure System |
Pressure Adjusting Range |
C : 140 bar H : 210 bar |
| Allowable Back Pressure | see note 1. | |
| Rated Current | C : 750 mA H : 700 mA |
|
| Coil Resistance | 10 Ω | |
| Magnetic Hysteresis | <3% | |
| Repeatability | <1% | |
| Weight | EFBG-03 : 18kgs EFBG-06 : 33kgs EFBG-10 : 58kgs |
|
Note:(1)Minimize resistance in oil return circuit. Use undependently
a pipe leading straightly to under oil level in oil tank.